Short answer: Size a micro DC gear motor in four steps: (1) convert your load into required output torque and output speed at the working point, (2) divide by gearbox ratio and efficiency to get the motor's required torque, (3) apply a service factor of 1.5–2.0 for start-up and shock loads, and (4) check that the resulting current fits your power supply and that the duty cycle stays inside the motor's thermal limit. Skipping step 3 is the most common cause of premature failure.
Sizing discipline matters more as the category grows: the global micro motor market is projected to expand from USD 48.0 billion in 2025 to USD 81.3 billion by 2033, a 6.9% CAGR (Grand View Research). More variants are being specified by product teams than by motor engineers, which puts the burden of correct sizing on the buyer.
Torque in N·m from a force at a radius:
If your load is quoted in kg·cm, convert: 1 kg·cm ≈ 0.0981 N·m.
Output power follows from torque and speed:
Always define the working point — the torque and speed the mechanism actually needs while moving — not stall torque and not free speed. A motor can satisfy both extremes on paper and still overheat in between.
Rearranged to find what the motor must deliver:
Efficiency (η) depends on the gearbox type, and it is where most sizing errors happen:
Gearbox type |
Typical ratio per stage |
Typical efficiency |
Notes |
Spur gear |
2–6:1 |
85–95% |
Cheap, compact, louder at high ratio |
Planetary |
3–10:1 |
90–97% |
High torque density, coaxial, low backlash options |
Worm gear |
10–60:1 |
40–90% |
High ratio in one stage, often self-locking, quiet |
Right-angle / bevel |
1–3:1 |
90–95% |
Changes axis direction |
Self-locking is the trade-off behind worm gears' low efficiency: a worm stage that cannot be back-driven holds a load with power off — ideal for lifting mechanisms — but you pay for it in heat and battery life.
Requirement: lift-and-rotate mechanism needing 0.5 N·m (≈5.1 kg·cm) at 60 rpm output, from a 12 V supply.
1. Output power: ω = 2π × 60 / 60 = 6.28 rad/s → P_out = 0.5 × 6.28 ≈
3.1 W
2. Pick a motor whose loaded speed is about 3,000 rpm → i = 3000 / 60 =
50:1
3. Two-stage planetary, η ≈ 0.9 × 0.9 = 0.81 → T_motor = 0.5 / (50 × 0.81) ≈
0.0123 N·m = 12.3 mN·m
4. Apply service factor 1.8 for start-up → design torque ≈
22 mN·m
5. Check current at that torque against the supply and the motor's continuous rating.
Now the same load with a worm gear stage at η = 0.5: T_motor = 0.5 / (50 × 0.5) = 20 mN·m, and 36 mN·m after service factor — roughly 60% more motor for the same output, in exchange for self-locking behaviour. That single efficiency assumption decides whether your battery pack lasts a shift or a day.
Three derating checks before you commit:
Thermal:
Duty cycle:
Ingress:
IEC 60529
. Sealing adds friction, so re-check torque after specifying it.
Sizing math gives you a target; matching it to a real motor is a search problem. Suppliers with large existing SKU libraries let you land on a proven platform instead of opening a new tooling program. TYHE Motor offers around 200 motor types and 2,000+ SKUs across micro DC motors, planetary gear motors, worm gear motors and stepper motors, with diameters from roughly 16 mm to 106 mm and CE and RoHS certification, plus a design-to-mass-production cycle of under 40 days when a custom variant is needed.
What service factor should I use?1.5 for smooth, well-lubricated mechanisms; 2.0 or more where loads shock, jam or start under load (locks, valves, lift mechanisms).
Should I size for stall torque?No. Size for the working point, then verify the motor survives brief stall without exceeding its thermal limit or your driver's current limit.
How do I reduce speed: gearbox or PWM?Both have a place. A gearbox multiplies torque and improves low-speed stability; PWM alone reduces speed but also available torque and can add audible noise. For high-ratio reduction, use gears.
Planetary or worm gear for a quiet product? Worm stages are usually quieter and self-locking but less efficient. Planetary stages are more efficient and compact; noise then depends on tooth accuracy. Verify with a measured dB(A) figure at a stated distance — see measurement guidance such as ISO 10302.
When is a stepper motor the better choice?When you need precise open-loop position control without an encoder — metering pumps, valve positioning, optical stages. When you need maximum torque per watt in rotation, a DC gear motor usually wins.
How do I confirm my calculation with a supplier?Send the working point (torque, speed, voltage), duty cycle, ambient temperature, noise target and life target in hours. A competent supplier returns a performance curve, not just a model number.
Torque and speed at the working point, divided by ratio and efficiency, multiplied by a service factor — then validated against thermal and environmental limits. Get those numbers into the RFQ and you will compare suppliers on real performance instead of on datasheet adjectives. Send the same inputs to TYHE Motor and the correct response is a performance curve at your working point plus a recommended platform from its 2,000+ SKU library — not a model number without data behind it.